How to Measure an Existing Folding Carton for an RFQ
An existing carton can start a quotation when the record states exactly what was measured. Keep observed sample dimensions separate from a converter's production drawing.
Choose and identify the objects
Give the product, erected carton and any spare flat carton separate IDs. Confirm product orientation and closure. Photograph front, back, top, bottom and open carton with its ID. Record wear, crushing or bowing. Do not calculate carton dimensions from product dimensions alone, or cut open the only approved sample to infer a dieline.
Mark orientation
The ECMA coding guide uses A, B and H and explains that their allocation depends on carton type. Its production definition measures from crease centers on a flat cutout. Do not claim an erected observation is that production measurement.
Measure in a repeatable sequence
- Let the sample return to normal shape; do not force it square.
- Measure marked outside directions between stated surfaces. Repeat where panels bow and keep each reading.
- Measure the clear inside loading path, noting flaps or seams that reduce it.
- Measure the product separately in intended orientation, including caps and accessories.
- Use an undamaged spare flat sample only when its status is known; label crease observations, not an approved dieline.
- Send a numbered physical sample or complete photo set.
Use one unit. State the tool and whether each reading is internal, external, clear opening or crease-center. Avoid universal length-width-height language when structure makes it ambiguous.
RFQ measurement record
| Object/direction | State and points | Observed | Supplier confirms |
|---|---|---|---|
| Face A | Erected, outside-to-outside, lower panel | 72.4 mm | Production A definition/target |
| Face A | Erected, upper panel | 72.9 mm | Handling of bow/method |
| Face B | Erected, outside-to-outside | 41.6 mm | Structure-specific B |
| H | Fold area to fold area as photographed | 118.2 mm | Production H/closure |
| Clear opening | Narrowest inside loading path | 39.1 mm | Product/loading fit |
| Product | Cap included, upright | See drawing | Clearance/sample check |
Add carton ID, photos, structure/ECMA code if known, artwork revision, product, loading direction, SKU quantities, destination and unknowns. Never replace an unknown with an estimate.
Approval boundary
The record makes RFQs comparable; it does not approve a dieline, tolerance, material, fit or production. Ask the converter to return proposed structure and dimensional definitions and verify them with the actual product. Before approving a range, define measurement conditions and acceptance limits for the proposed structure.
When these observations support an approved supplier change, place them inside a controlled replication and revalidation pack.
For applicable HS PACKFACTORY projects, samples are made in 3–7 days after specifications, files and any agreed fees are confirmed, depending on product complexity and material availability. The timing should be considered separately for blank and printed samples. Completed samples can be reviewed through photos or video. International sample courier charges are paid separately, and transit time is additional. Complex projects require a separate arrangement.
When the measurements disagree
Keep the original readings when two measurements differ. A repeated reading, a different measurement basis and a damaged sample are different records. Ask the converter to state which observation was used for the quotation and which production dimension still needs approval.
| Record | What to attach | Decision still required |
|---|---|---|
| Two different readings | Sample ID, tool, unit, location and photo for each reading | Repeat under the same stated method; retain both original entries |
| Inside versus outside | Label the surface and loading path on each photo | Converter returns its production dimension definition |
| Worn or distorted sample | Photograph the damage and identify a spare, if available | Confirm the reference used for quotation before approving fit |
Attach the observation register to the supplier-transition evidence pack. An unresolved observation may be a quotation assumption; it is not an approved production target. supplier-transition evidence pack
Frequently asked questions
Internal or external dimensions?
Send both when reliably measured and label them. The converter still defines production dimensions.
Can I subtract board thickness?
No universal formula is safe across structures, folds and methods. Record direct observations.
Must I flatten the carton?
No. Preserve the only reference; use a spare only when its status is known.
Is the illustration a dieline?
No. It only fixes orientation.